This page should be read in conjunction with How Plume Plotter Works. It provides more details specific to the Coatbridge version of Plume Plotter.
Building measurements are taken from [1]. This image shows the layout of the stack and buildings modelled. North is at the top; colours and numbers indicate the height of the buildings and the stack.

These are taken from [1]:
The following values are used for albedo, Bowen ratio and roughness length. The "urban option" of AERMOD was used, with the urban roughness as specified in [1]:
The emission rates of pollutants are taken from [1]:
| Pollutant | Emission rate per second |
|---|---|
| Oxides of nitrogen | 11.18 g |
| Particulates | 559 mg |
| Sulphur dioxide | 2.795 g |
| Carbon monoxide | 2.795 g |
| Hydrogen chloride | 559 mg |
| Hydrogen flouride | 55.9 mg |
| VOCs | 559 mg |
| Cadmium & Thallium | 2.795 mg |
| Mercury | 2.795 mg |
| Other metals | 27.95 mg |
| Dioxins and furans | 5.59 ng |
The background levels of pollutants are taken from [1]:
| Pollutant | Background concentration per m3 |
|---|---|
| Oxides of nitrogen | 16 μg |
| Particulates | 13.1 μg |
| Sulphur dioxide | N/A |
| Carbon monoxide | N/A |
| Hydrogen chloride | N/A |
| Hydrogen flouride | N/A |
| VOCs | N/A |
| Cadmium & Thallium | N/A |
| Mercury | N/A |
| Other metals | N/A |
| Dioxins and furans | N/A |
Weather data is taken from METAR reports from a local airport: Glasgow.
Upper air data is the latest reported by the Albemarle upper air station.