Details of Corby (Gretton) Plume Plotter

This page should be read in conjunction with How Plume Plotter Works. It provides more details specific to the Corby (Gretton) version of Plume Plotter.

Stacks and buildings

Building measurements are taken from [1]. The image below shows the layout of the stack and buildings modelled. North is at the top; colours and numbers indicate the height of the buildings and the stack:

Stack measurements

All of these are taken from [1]:

The following values are used for albedo, Bowen ratio and roughness length. Albedo and roughness length are as specified in [1]:

Emissions

The emission rates of pollutants are taken from [1].

PollutantEmission rate
per second
Oxides of nitrogen5.2 g
Particulates200 mg
Sulphur dioxide1.3 g
Carbon monoxide2.2 g
TOC400 mg
Hydrogen chloride300 mg
Hydrogen flouride40 mg
Cadmium and thallium900 μg
Mercury400 μg
Other metals10 mg
Ammonia400 mg
Dioxins and furans2.6 ng
PAHs6.5 μg
PCB3.5 ng

Background levels

The background levels of pollutants are taken from [1]. These are:

PollutantBackground
concentration per m3
Oxides of nitrogen14.9 μg
Particulates13.1 μg
Sulphur dioxide2.2 μg
Carbon monoxide246 μg
TOC540 ng
Hydrogen chloride210 ng
Hydrogen flourideN/A
Cadmium and thallium100 pg
MercuryN/A
Other metals14.8 ng
Ammonia1.95 μg
Dioxins and furans10.9 fg
PAHs150 pg
PCBN/A

Weather data

Weather data is taken from METAR reports from a local airport: Wittering RAF.

Upper air data is the latest reported by the Nottingham upper air station.

References

1. Air Quality Assessment: Corby Green Power Limited, Gretton Brook Road. Air Quality Consultants Ltd. April 2020.