This page should be read in conjunction with How Plume Plotter Works. It provides more details specific to the Corby (Gretton) version of Plume Plotter.
Building measurements are taken from [1]. The image below shows the layout of the stack and buildings modelled. North is at the top; colours and numbers indicate the height of the buildings and the stack:
All of these are taken from [1]:
The following values are used for albedo, Bowen ratio and roughness length. Albedo and roughness length are as specified in [1]:
The emission rates of pollutants are taken from [1].
Pollutant | Emission rate per second |
---|---|
Oxides of nitrogen | 5.2 g |
Particulates | 200 mg |
Sulphur dioxide | 1.3 g |
Carbon monoxide | 2.2 g |
TOC | 400 mg |
Hydrogen chloride | 300 mg |
Hydrogen flouride | 40 mg |
Cadmium and thallium | 900 μg |
Mercury | 400 μg |
Other metals | 10 mg |
Ammonia | 400 mg |
Dioxins and furans | 2.6 ng |
PAHs | 6.5 μg |
PCB | 3.5 ng |
The background levels of pollutants are taken from [1]. These are:
Pollutant | Background concentration per m3 |
---|---|
Oxides of nitrogen | 14.9 μg |
Particulates | 13.1 μg |
Sulphur dioxide | 2.2 μg |
Carbon monoxide | 246 μg |
TOC | 540 ng |
Hydrogen chloride | 210 ng |
Hydrogen flouride | N/A |
Cadmium and thallium | 100 pg |
Mercury | N/A |
Other metals | 14.8 ng |
Ammonia | 1.95 μg |
Dioxins and furans | 10.9 fg |
PAHs | 150 pg |
PCB | N/A |
Weather data is taken from METAR reports from a local airport: Wittering RAF.
Upper air data is the latest reported by the Nottingham upper air station.