Details of Norwich Plume Plotter

This page should be read in conjunction with How Plume Plotter Works. It provides more details specific to the Norwich version of Plume Plotter.

Stack measurements

All of these are taken from [1]:

Emissions

The emission rates of pollutants are taken from [1]. These are:

PollutantEmission rate
per second
Oxides of nitrogen8.746 g
Sulphur dioxide8.746 g
Particulates875 mg
Carbon monoxide16.4 g
Hydrogen chloride1.312 g
Ammonia656 mg

Background levels

The background levels of pollutants are taken from [1]. These are:

PollutantBackground
concentration per m3
Oxides of nitrogen22.8 μg
Sulphur dioxide6.63 μg
Particulates20.41 μg
Carbon monoxide458 μg
Hydrogen chloride490 ng
Ammonia1.92 μg

Weather data

Weather data is taken from METAR reports from a local airport: Norwich Weather Centre.

Upper air data is the latest reported by the Nottingham upper air station.

References

1. AXIS GENERATION PARK NORWICH DISPERSION MODELLING REPORT, Fichtner, July 2015.