This page should be read in conjunction with How Plume Plotter Works. It provides more details specific to the Swansea version of Plume Plotter.
Building measurements are taken from the building plans. This image shows the layout of the stack and buildings modelled. North is at the top; colours and numbers indicate the height of the buildings and the stack.
All of these are taken from [1]:
The following values are used for albedo, Bowen ratio, and roughness length. None of these are specified in [1]:
The emission rates of pollutants are taken from [1]:
Pollutant | Emission rate per second |
---|---|
Oxides of nitrogen | 1.387 g |
Particulates | 69 mg |
Sulphur dioxide | 347 mg |
Carbon monoxide | 347 mg |
Hydrogen chloride | 69 mg |
Hydrogen fluoride | 6.93 mg |
VOCs | 69 mg |
Cadmium and thallium | 350 μg |
Mercury | 350 μg |
Other metals | 3.47 mg |
Dioxins and furans | 693.3 pg |
PAHs | 119.5 ng |
PCBs | 63.79 pg |
The background levels of pollutants are taken from [1]:
Pollutant | Background concentration per m3 |
---|---|
Oxides of nitrogen | 12.64 μg |
Particulates | 12.73 μg |
Sulphur dioxide | 3.33 μg |
Carbon monoxide | 112 μg |
Hydrogen chloride | 212 ng |
Hydrogen fluoride | N/A |
VOCs | 450 ng |
Cadmium and thallium | 320 pg |
Mercury | 3.5 ng |
Other metals | 70.98 ng |
Dioxins and furans | N/A |
PAHs | 400 pg |
PCBs | N/A |
Weather data is taken from METAR reports from a local airport: Cardiff.
Upper air data is the latest reported by the Camborne upper air station.