This page should be read in conjunction with How Plume Plotter Works. It provides more details specific to the Tarago version of Plume Plotter.
The proposed incinerator's building layout is not known, so it is (unrealistically) assumed that there are no buildings near the stack. The presence of such buildings would cause building downwash and increase ground-level concentrations.
Apart from the stack location, these are estimated from the proposed incinerator's annual throughput (380000 tonnes per annum):
The following values are used for albedo, Bowen ratio and roughness length:
The emission rates of pollutants are estimated from the proposed incinerator's annual throughput (380000 tonnes per annum), using the EU limits (2019 BREF) on pollutant concentrations:
Pollutant | Emission rate per second |
---|---|
Oxides of nitrogen | 10.15 g |
Particulates | 422.9 mg |
TOC | 845.8 mg |
Hydrogen chloride | 507.5 mg |
Hydrogen flouride | 84.58 mg |
Sulphur dioxide | 2.538 g |
Carbon monoxide | 4.229 g |
Cadmium and thallium | 1.692 mg |
Mercury | 1.692 mg |
Other metals | 25.37 mg |
Dioxins and furans | 5.075 ng |
The background levels of pollutants used are not very local: they are taken from the 2016 proposal for the Eastern Creek incinerator in Western Sydney:
Pollutant | Background concentration per m3 |
---|---|
Oxides of nitrogen | 21.6 μg |
Particulates | 17.6 μg |
TOC | N/A |
Hydrogen chloride | N/A |
Hydrogen flouride | N/A |
Sulphur dioxide | 1.5 μg |
Carbon monoxide | N/A |
Cadmium and thallium | N/A |
Mercury | N/A |
Other metals | N/A |
Dioxins and furans | N/A |
Weather data is taken from METAR reports from a local airport: Goulburn.
Upper air data is the latest reported by the Moree Mo upper air station.